Upsilon in d+Au 200 GeV BEMC Towers Hits
Run days


High Energy Towers Hits (tower energy>3GeV) in year 2007




















High Energy Towers Hits (tower energy>3GeV) in year 2008


























========================================All run days======================================
pt>3GeV/c for tracks
E_tower>3 for towers





|eta|<0.9


0.9<|eta|<1


Conclusions:
main dead area:
-0.4<eta<-0.2 && -1.75<phi<-2.3
0.4<eta<0.6 && 1.9<phi<-2.3
-0.4<eta<-0.2 && 1.45<phi<1.9
hot area:
|eta|>0.9
This can roughly explain the shape of eta distribution of matched tracks

Upsilon Signals
cuts: |vz|<30cm && |eta|<1 && |nFitPoints|>=23 && dEdx cut for eID
like-sign BG calculation: BG = 2 * sqrt(++ * --)
|eta|<1 Integral(7,11)=129

cuts: |vz|<30cm && |eta|<1 && |nFitPoints|>=23 && dEdx cut for eID
like-sign BG calculation: BG = 2 * sqrt(++ * --)
|eta|<0.8 Integral(7,11)=86 (consistency check: 129*0.8^2=83)